Encyclopaedia Index
Making PATCHwise source settings
- Scroll
'Dependent variable'
list in 'PATCH and COVAL' section
of sub-menu dialog box.
- Select the variable.
- Click on
radio buttons
next to either 'Coefficient' or
'Value' to activate the settings of constant values for
Coefficient and Values, if appropriate.
- Specify the
constant values
of either Coefficient or Value,
if any, in the fields provided.
- Scroll to view the list of sample expressions for Coefficient
and Values.
- Select, edit and/or type-in the
expressions for
Coefficient
and/or
Value
in the fields provided.
- Select appropriate
PATCH type
by scrolling the list.
- Specify the
extents of PATCH
in terms of first cell/time moment index,
'Position', and number of cells/time intervals, 'Size', in the coordinate
directions, X, Y,Z, and time,T, in the fields under 'PATCH
region'.
- Change
'PATCH name',
if desired.
- Click
'OK'
to implement settings or
'Cancel' to cancel them.