A list of the sample PATCH and COVAL statements which activate the number of conditions extracted from the existing GXCCVG collection are shown below.
They are activated by following standart statements:
WALL (SOUTH,SOUTH,1,NX,1,1,1,NZ,1,1)
COVAL(SOUTH,UC1,1.0/PRNDTL(UC1),UC1WALL)
COVAL(SOUTH,WC1,1.0/PRNDTL(WC1),WC1WALL)
WALL (SOUTH,SOUTH,1,NX,1,1,1,NZ,1,1)
COVAL(SOUTH,UC1,1.0/PRNDTL(UC1),GRND)
COVAL(SOUTH,VC1,1.0/PRNDTL(VC1),GRND)
COVAL(SOUTH,WC1,1.0/PRNDTL(WC1),GRND)
moving wall:
UC1E=UC1 of east wall | VC1E=VC1 of east wall | WC1E=WC1 of east wall |
UC1W=UC1 of west wall | VC1W=VC1 of west wall | WC1W=WC1 of west wall |
UC1N=UC1 of north wall | VC1N=VC1 of north wall | WC1N=WC1 of north wall |
UC1S=UC1 of south wall | VC1S=VC1 of south wall | WC1S=WC1 of south wall |
UC1H=UC1 of high wall | VC1H=VC1 of high wall | WC1H=WC1 of high wall |
UC1L=UC1 of low wall | VC1L=VC1 of low wall | WC1L=WC1 of low wall |
They are activated by following standart statements:
WALL (SOUTH,SOUTH,1,NX,1,1,1,NZ,1,1)
COVAL(SOUTH,UC1,GRND2,UC1WALL)
COVAL(SOUTH,WC1,GRND2,WC1WALL)
WALL (SOUTH,SOUTH,1,NX,1,1,1,NZ,1,1)
COVAL(SOUTH,UC1,GRND,GRND)
COVAL(SOUTH,VC1,GRND,GRND)
COVAL(SOUTH,WC1,GRND,GRND)
moving wall:
UC1E=UC1 of east wall | VC1E=VC1 of east wall | WC1E=WC1 of east wall |
UC1W=UC1 of west wall | VC1W=VC1 of west wall | WC1W=WC1 of west wall |
UC1N=UC1 of north wall | VC1N=VC1 of north wall | WC1N=WC1 of north wall |
UC1S=UC1 of south wall | VC1S=VC1 of south wall | WC1S=WC1 of south wall |
UC1H=UC1 of high wall | VC1H=VC1 of high wall | WC1H=WC1 of high wall |
UC1L=UC1 of low wall | VC1L=VC1 of low wall | WC1L=WC1 of low wall |
No special statements are needed. When CCV=T the subroutine GENBGR is called from GXCCVG to re-write the rate of turbulent energy production, see Section 6.2
PATCH(BUOY,PHASEM,1,1,1,NY,1,NZ,1,1)
COVAL(BUOY,WC1,FIXFLU,GRND3)
wbs