BY : S Zhubrin - CHAM-MEI, E Lopez - INP-Grenoble
Date: 1997 PHOENICS Version: 3.0
q=c*h*(gh)**(1/2).
This formula governs the water level at the weirs where the outlets
are located, and here
q - flow rate per unit width or weir
h - is the height of the fluid above the weir
g - is the acceleration of gravity
c - overflow coefficient
The following illustrates the geometry and velocity results.
Geometry created by VR and using ASAP.(Some objects were removed for viewing)
A view of the inlet and curved pipe created by VR and ASAP.
Velocity distribution at the distributor outlet.
wbs