TALK=T;RUN(1,1) DISPLAY In this example we have a gas leak from a small breach in a pipe, within a large equipment room. To "capture" the scale of the gas leak (of the order of 1mm) within the large room (characteristic length 1m) is difficult to do with a single grid. Here a sequence of 4 successively embedded grids are used to resolve both the leak aperture itself and the resulting jet. The gas is heavier than air, and the model includes bouyancy effects. A fixed turbulent viscosity based upon experimental results for the round turbulent jet has been used. NOTE !!! The size of F-array should be at least 2000000. This Q1 file includes Photon Use information. --------------------------------------------------------- ENDDIS PHOTON USE p use patgeo vi x set con scale range on set vec av off set vec ref 10 mvec 1 i 1 sh mvec 2 i 1 sh pause cl use patgeo con cgas i 1 fi 0 0.25 0.001 pause vi 1 1 1 mvec 1 j 1 sh ENDUSE