TALK=T;RUN(1,1)
DISPLAY
In-Form is used to set an initial sinusoidal temperature
in an insulated slab of aluminium.
The temperature distribution flattens with time, retaining
however its sinusoidal shape, as is made evident by the
line-printer plots elicited by PATCH(PLOT,PROFIL,,,,,
Setting IDISPA=20 causes a parphi file to be created, with
20 time intervals, enabling the temperature variation to be
viewed via PHOTON.
ENDDIS
PHOTON USE
p
parphi
500 1 1
msg temperature contours; vertical direction is slab thickness
msg horizontal direction is time
msg type e to end WinPHOTON session
con tem1 y 1 fi;0.001
ENDUSE
************************************************************
Group 1. Run Title and Number
************************************************************
************************************************************
TEXT(decay of temp. profile in metal slab )
************************************************************
************************************************************
IRUNN = 1 ;LIBREF = 14
************************************************************
Group 2. Time dependence
STEADY = F
* Set overall time and no. of steps
TFIRST =0. ;TLAST =1000.
FSTEP = 1 ;LSTEP = 100
TFRAC(1)=1.0E-02 ;TFRAC(11)=0.11
TFRAC(21)=0.21 ;TFRAC(31)=0.31
TFRAC(41)=0.41 ;TFRAC(51)=0.51
TFRAC(61)=0.61 ;TFRAC(71)=0.71
TFRAC(81)=0.81 ;TFRAC(91)=0.91
************************************************************
Group 3. X-Direction Grid Spacing
CARTES = T
NX = 10
XULAST =1.
XFRAC(1)=0.1 ;XFRAC(2)=0.2
XFRAC(3)=0.3 ;XFRAC(4)=0.4
XFRAC(5)=0.5 ;XFRAC(6)=0.6
XFRAC(7)=0.7 ;XFRAC(8)=0.8
XFRAC(9)=0.9 ;XFRAC(10)=1.
************************************************************
Group 4. Y-Direction Grid Spacing
NY = 1
YVLAST =1.
YFRAC(1)=1.
************************************************************
Group 5. Z-Direction Grid Spacing
PARAB = F
NZ = 1
ZWLAST =1.
ZFRAC(1)=1.
************************************************************
Group 6. Body-Fitted Coordinates
************************************************************
Group 7. Variables: STOREd,SOLVEd,NAMEd
ONEPHS = T
NAME(148)=PRPS ;NAME(149)=SPH1
NAME(150)=TEM1
* Y in SOLUTN argument list denotes:
* 1-stored 2-solved 3-whole-field
* 4-point-by-point 5-explicit 6-harmonic averaging
SOLUTN(PRPS,Y,N,N,N,N,Y)
SOLUTN(SPH1,Y,N,N,N,N,N)
SOLUTN(TEM1,Y,Y,N,N,N,Y)
PRPS = 148
************************************************************
Group 8. Terms & Devices
* Y in TERMS argument list denotes:
* 1-built-in source 2-convection 3-diffusion 4-transient
* 5-first phase variable 6-interphase transport
TERMS(TEM1,N,Y,Y,Y,Y,Y)
DIFCUT =0.5 ;ZDIFAC =1.
GALA = F ;ADDDIF = F
ISOLX = -1 ;ISOLY = -1 ;ISOLZ = -1
************************************************************
Group 9. Properties used if PRPS is not
stored, and where PRPS = -1.0 if it is!
RHO1 =1. ;TMP1 =0. ;EL1 =0.
TSURR =0. ;TEMP0 =0. ;PRESS0 =0.
DVO1DT =0. ;DRH1DP =0.
EMISS =0. ;SCATT =0.
RADIA =0. ;RADIB =0.
ENUL =1.0E-05 ;ENUT =0.
PRNDTL(TEM1)=1.
PRT(TEM1)=1.
CP1 =1. ;CP2 =1.
************************************************************
Group 10.Inter-Phase Transfer Processes
************************************************************
Group 11.Initial field variables (PHIs)
FIINIT(PRPS)=100. ;FIINIT(SPH1)=1.0E-10
FIINIT(TEM1)=1.0E-10
No PATCHes yet used for this Group
INIADD = F
FSWEEP = 1
NAMFI =CHAM
************************************************************
Group 12. Patchwise adjustment of terms
Patches for this group are printed with those
for Group 13.
Their names begin either with GP12 or &
************************************************************
Group 13. Boundary & Special Sources
No PATCHes yet used for this Group
XCYCLE = F
EGWF = T
WALLCO = GRND2
************************************************************
Group 14. Downstream Pressure For PARAB
************************************************************
Group 15. Terminate Sweeps
LSWEEP = 5 ;ISWC1 = 1
LITHYD = 1 ;LITFLX = 1 ;LITC = 1 ;ITHC1 = 1
SELREF = T
RESFAC =1.0E-05
************************************************************
Group 16. Terminate Iterations
LITER(TEM1)=20
ENDIT(TEM1)=1.0E-03
************************************************************
Group 17. Relaxation
RELAX(PRPS,LINRLX,1.)
RELAX(SPH1,LINRLX,1.)
RELAX(TEM1,FALSDT,1.0E+09)
OVRRLX =0.
EXPERT = F ;NNORSL = F
************************************************************
Group 18. Limits
VARMAX(PRPS)=1.0E+10 ;VARMIN(PRPS)=-1.0E+10
VARMAX(SPH1)=1.0E+10 ;VARMIN(SPH1)=-1.0E+10
VARMAX(TEM1)=1.0E+10 ;VARMIN(TEM1)=-1.0E+10
************************************************************
Group 19. Data transmitted to GROUND
PARSOL = F
ISG62 = 1
SPEDAT(SET,INITIAL,TEM1,C,=SIN(XG*3.14159))
SPEDAT(SET,GXMONI,PLOTALL,L,T)
SPEDAT(SET,MATERIAL,100,L,T)
************************************************************
Group 20. Preliminary Printout
************************************************************
Group 21. Print-out of Variables
INIFLD = F ;SUBWGR = F
* Y in OUTPUT argument list denotes:
* 1-field 2-correction-eq. monitor 3-selective dumping
* 4-whole-field residual 5-spot-value table 6-residual table
OUTPUT(PRPS,Y,N,Y,N,N,N)
OUTPUT(SPH1,N,N,Y,Y,N,N)
OUTPUT(TEM1,Y,N,Y,Y,Y,Y)
************************************************************
Group 22. Monitor Print-Out
IXMON = 1 ;IYMON = 1 ;IZMON = 1
NPRMON = 100000 ;NPRMNT = 1 ;TSTSWP = 1
UWATCH = T ;USTEER = T
HIGHLO = F
************************************************************
Group 23.Field Print-Out & Plot Control
NPRINT = 100000 ;NUMCLS = 5
NTPRIN = 10 ;ISTPRF = 1 ;ISTPRL = 100000
NXPRIN = 1 ;IXPRF = 1 ;IXPRL = 10000
IPLTF = 1 ;IPLTL = -1 ;NPLT = -1
ISWPRF = 1 ;ISWPRL = 100000
ITABL = 3 ;IPROF = 1
ABSIZ =0.5 ;ORSIZ =0.4
NTZPRF = 1 ;NCOLPF = 50
ICHR = 2 ;NCOLCO = 45 ;NROWCO = 20
PATCH(PLOT ,PROFIL, 1, 10, 1, 1, 1, 1, 1, 100)
PLOT(PLOT ,TEM1,0. ,0. )
************************************************************
Group 24. Dumps For Restarts
SAVE = T ;NOWIPE = F
NSAVE =CHAM
IDISPA = 20 ;IDISPB = 0 ;IDISPC = 0
STOP