L(797) CASE 9 As for case 8 but with allowance for heat capacity of metal GROUP 1. Run title TEXT(Case 9; Allowance For Metal Capac TITLE User-defined variables: REAL(CAPM,COEF1O,COEF2O,COEFMO) CAPM=0.1;COEFMO=CAPM/DELT COEF12=COEF1*COEF2/(COEF1+COEF2+COEFMO) COEF1O=COEF1*COEFMO/(COEF1+COEF2+COEFMO) COEF2O=COEF2*COEFMO/(COEF1+COEF2+COEFMO) Arrange that metal temperature, named METL, occupies store with index 1 above 2NDH and 2 above 1STH. SOLVE(C1);NAME(C1)=METL;TERMS(METL,N,N,N,Y,N,N) FIINIT(1STH)=T1IN;FIINIT(METL)=0.5*(T1IN+T2IN) COVAL(INLET1,METL,ONLYMS,SAME) Repeat the COVALs using COEF12, which has changed since it was calculated for case 8. COVAL(NEPLUS,1STH,COEF12,LOCNE) COVAL(NEMINUS,2NDH,COEF12,LOCNE) Connect shell fluid with old metal PATCH(NEO2,VOLUME,1,NX,1,NY,1,NZ,1,LSTEP) COVAL(NEO2,1STH,COEF1O,LOCNE) Connect metal with shell fluid PATCH(NEM2,VOLUME,1,NX,1,NY,1,NZ,1,LSTEP) COVAL(NEM2,METL,COEF1O,LOCNE) Connect tube fluid with old metal PATCH(NEO1,VOLUME,1,NX,1,NY,1,NZ,1,LSTEP) COVAL(NEO1,2NDH,COEF2O,LOCNE) Connect metal with tube fluid PATCH(NEM1,VOLUME,1,NX,1,NY,1,NZ,1,LSTEP) COVAL(NEM1,METL,COEF2O,LOCNE) Transient for metal COVAL(NEOLD,METL,CAPM/DELT,LOCNE) LSWEEP=50 PLOT(TABMAP,METL,0.0,10.0) PLOT(TABYEQ3,METL,0.0,10.0) PLOT(PASS1,METL,T2IN,T1IN) PLOT(PASS2,METL,T2IN,T1IN) PLOT(PASS3,METL,T2IN,T1IN) PLOT(PASS4,METL,T2IN,T1IN) PLOT(PASS5,METL,T2IN,T1IN) PLOT(TIMEPLOT,METL,T2IN,T1IN)