L(222) GROUP 1. Run title and other preliminaries TEXT(2 Quadrant Polar Wind Flow TITLE Parallel flow is prescribed at the circumferential boundary of a polar grid, in order to demonstrate that EARTH predicts a uniform parallel flow within the domain. The results show that the curvilinear grid does not distort the flow field. VIN=25.0 INTEGER(IX1);IX1=NX/2 GROUP 3. X-direction grid specification GRDPWR(X,12,PI,1.0) GROUP 13. Boundary conditions and special sources PATCH( PINF,CELL,1,NX,NY,NY,1,NZ,1,1) COVAL( PINF,P1,1.0E6,0.0 ) COVAL( PINF,U1,ONLYMS,0.0);COVAL(PINF,V1,ONLYMS,0.0) PATCH(UPOL,CELL,1,IX1,NY,NY,1,1,1,1) COVAL(UPOL,U1,FIXVAL,SETSPEED) PATCH(VPOL,CELL,1,IX1,NY-1,NY-1,1,1,1,1) COVAL(VPOL,V1,FIXVAL,SETSPEED) GROUP 15. Termination of sweeps LSWEEP=100;RESFAC=1.E-06 GROUP 17. Under-relaxation devices RELAX(U1,FALSDT,0.07);RELAX(V1,FALSDT,0.07) GROUP 19. Special calls from EARTH to GROUND POLRA=-VIN GROUP 22. Spot-value print-out IXMON=11;IYMON=8 GROUP 23. Field print-out and plot control NYPRIN=NY/5